What This Timer Does

A manually set, wind-up timer gives you simple, reliable control over your bath fan or whole house fan without needing to wire a digital switch. The 12 Hour Timer for Whole House Fans and Bathroom Fans installs in your wall and offers a 1-12 hour control setting with an off function. You turn the dial to set how long the fan runs, and the timer winds down automatically, turning the fan off when time is up.

Timer at a Glance

  • 12 Hour Timer for Whole House Fans and Bathroom Fans: This manually set, wind-up timer installs in your wall and has a 1-12 hour control setting with off function. Knowing the timer is wind-up and offers a 1-12 hour range helps you decide if it fits your daily routine. No batteries or digital programming needed.
    12 Hour Timer for Whole House Fans and Bathroom Fans
    12 Hour Timer for Whole House Fans and Bathroom Fans
  • 12 Hour Timer for Whole House Fans and Bathroom Fans: For use with whole house fans and bathroom fans. Confirms the timer works with the two most common fan types in homes. If you have a different fan type, check compatibility before buying.

Installing the Timer

Installation follows standard wiring practices for a wall switch. If you are not comfortable working with electrical wiring, hire a licensed electrician.

  1. Turn off power: Switch off the circuit breaker that supplies the fan circuit. Confirm power is off with a voltage tester.
  2. Remove the existing switch: Unscrew the wall plate and existing switch. Disconnect the wires, noting which is line (power) and which is load (to the fan).
  3. Connect the timer: The timer has two wires. Connect one to the line wire and the other to the load wire. Use wire nuts and ensure connections are tight.
  4. Mount the timer: Gently push the wires into the box, align the timer with the screw holes, and secure it. Attach the wall plate.
  5. Restore power and test: Turn the circuit breaker back on. Turn the timer dial to a short setting, like 1 hour. The fan should start and stop when time expires.

Using the Timer Day to Day

To operate, simply turn the dial clockwise to the desired run time (1 to 12 hours). The timer will wind down and turn the fan off automatically. To stop the fan early, turn the dial to the off position. The timer is mechanical, so it does not lose settings during a power outage. There is no battery to replace.

Compatibility and Limitations

The 12 Hour Timer is designed for whole house fans and bathroom fans. It is a single-pole, single-throw device and replaces a standard wall switch. It is not suitable for three-way switching or for fans that require a neutral wire for digital controls. If your fan has a separate light, you will need a separate switch or a combined unit. The supplied information does not cover dimming or multi-speed fan control, so use it only for on/off timing.