Quick answer
This blade kit fits only 30 in. belt-driven whole house fans and is compatible with model CX30BD2SPD. If your fan matches, replace the entire blade assembly rather than individual blades, and plan for up to 10 business days of lead time because the kit is made to order.
Why the whole assembly matters on a belt drive fan
On a belt drive whole house fan, the blades, spider hub, and fasteners work as one balanced unit. Replacing only a chipped or bent blade can leave the assembly out of balance, which shows up as vibration and extra load on the motor and bearings. The kit supplies the four blades, spider/hub, screws, and locking nuts together so the rotating mass stays matched.
When replacement is the right call
Inspect the blade assembly before ordering. Cracks at the blade root, missing balance weights, or a hub that no longer grips the shaft are all reasons to replace the assembly. If the blades are intact and the fan simply will not turn, the belt or motor may be the fault, and a blade kit will not fix that.
Step-by-step blade kit replacement
- Confirm model and drive type: Find the fan's model plate and verify it reads CX30BD2SPD and that the fan is belt driven. Common mistake: ordering by blade diameter alone and missing the belt drive requirement. Snap a photo of the model plate before you order so you can compare it to the kit listing.
- Shut off power at the breaker: Switch off the circuit that feeds the whole house fan and lock the panel if possible. Common mistake: relying on a wall switch, which may not cut all power to the attic unit. Use a voltage tester at the fan wiring to confirm the power is off before touching the blades.
- Remove the old blade assembly: Disconnect the fan from power, then unbolt the old spider/hub from the shaft and lift the blades out. Keep the mounting hardware organized. Common mistake: prying on the blades to loosen a stuck hub, which can bend the shaft. If the hub will not release, apply penetrating oil and let it sit rather than forcing it.
- Assemble the new kit on the bench: Attach the four blades to the new spider/hub using the supplied screws and locking nuts, and snug them evenly. Common mistake: fully tightening one blade before the others, which can distort the hub. Tighten in a cross pattern so the assembly stays flat.
- Mount the assembly and check clearance: Slide the new hub onto the shaft and secure it, then rotate the blades by hand through a full turn. Common mistake: skipping the hand turn and discovering a blade strike only after power is restored. Confirm at least a finger's width of clearance between each blade tip and the fan housing.
- Restore power and test for vibration: Turn the breaker back on and run the fan through its speed settings, listening and watching for shake. Common mistake: ignoring new vibration, which often means a loose blade or an unevenly tightened hub. If vibration persists, recheck blade screw torque and hub seating before running the fan again.
Product facts
- Fan Blade Kit for 30 In. Belt Drive Whole House Fans: The kit includes 4 blades, a spider/hub, and screws and locking nuts for assembly. You get every fastening part needed to rebuild the rotating assembly in one order, so you are not hunting for matching hardware mid-job.

Fan Blade Kit for 30 In. Belt Drive Whole House Fans - Fan Blade Kit for 30 In. Belt Drive Whole House Fans: It is made to order and may take up to 10 business days before shipping. Schedule the repair around that lead time, especially if the fan is your main source of ventilation in warm weather.
- Fan Blade Kit for 30 In. Belt Drive Whole House Fans: It is for use only with 30 in. belt-driven whole house fans and is compatible with model CX30BD2SPD. Check your fan's model and drive type first; a direct drive or different size fan will not accept this kit.